Stacks Image 4927
Stacks Image 4929
Product Description
Stacks Image 4938
Triple Seal Energy Sill Sealeris the combination of the gasket seal of ENERGY SILL SEAL and the air & moisture barrier protection of MAX-SHIELD. This unification of products gives you the ultimate protection from air & moisture infiltration that can deplete your building of up to 40% of its energy efficiency. 3X sealing provides three adhesive membrane areas for maximum protection.
Energy Sill Seal is a permanent gasket seal designed to eliminate air and moisture from entering between the foundation and the floor deck. Made from closed cell cross-linked polyethylene, Energy Sill Seal has the ability to compress and re-adjust for a permanent perfect fit during construction and when the building settles or moves.

Max-Shield™Perimeter Sill Flashing is made with an extremely durable puncture resistant facer that has over 500% elongation. It offers 100% protection from both air & moisture infiltration and has the ability to expand and contract with extreme substrate movement assuring a permanent long term water tight seal.
Basic Uses
Designed to seal up the most crucial area in a building, the interface between a floor deck/mud sill and top of the foundation.
Features
• Full plate seal, not just internal edge
• Stops moisture and air infiltration at joint
• Separates and provides a thermal break
• Adheres to damp, wet and cold surfaces
• Peel and stick for easy install
• Maintains a permanent seal
• Crossed Linked for Anti-Crush Properties
• Reduces Heating and Cool Costs
• Prevents harmful Garage Fumes from Entering
• Exceeds Local and National Codes
• Help Stop Mold and Mildew
• No Primer Required
• Widest Range of Installation Temperatures
• Workable for Precise Placement
• Compatible with All Building Materials
• Prevents Air and Moisture Infiltration
• Strongest Tape on the Market
• Moves With Joint Expansion and Contraction
• Conforms to Surfaces Irregularities
• Stays Flexible Forever
• Peel and Stick Installation
• Stops Energy Loss
• Stops Bugs from Entering at Joint
Additional Features
Stacks Image 4979
Peel and Stick application for fast, accurate installation.
Stacks Image 4985
Able to withstand movement and still stay incredibly strong under the harshest conditions.
Stacks Image 4992
By not allowing air and moisture to enter into the building envelope, one can save on utility cost.
Stacks Image 4999
This product will stay Flexible Forever giving it the advantage of moving with the expansion and contraction of the building.
Stacks Image 5006
Crossed linked to provide elongation with recovery properties.
Stacks Image 5030
Can be installed successfully at temperature as low as -30° F.
Stacks Image 5037
Made with Pride in the
United State of America.
Stacks Image 5051
Designed and manufactured with environmental awareness, this product is VOC Complaint and earth friendly.
Stacks Image 5044
Micro-Grab Technology is the most advance adhesive in the world with vastly superior properties including hot, cold and wet weather adhesion.
Available Sizes

Sizes

75 Lin. Ft.

Kits/Case

6

Lbs./Case

28

Cases/Pallet

48

Customizable Sizes Available

Box Sill Energy Loss at the Plate Line

Considered the most crucial area to seal up in a building is the interface between a floor deck/mud sill and top of the foundation - the box sill area. Test studies through the United States Department of Energy at Oakridge Laboratories have shown that a building can lose up to 40% of its total energy efficiency through air leakage if not properly sealed.
Seal Box Sill
The photo above using scientific instrumentation energy loss at the box sill area. The dark orange color represents the highest loss. Reducing the amount of air that leaks in and out of the box sill area is a cost-effective way to cut heating and cooling costs, improve durability, increase comfort, and create a healthier indoor environment. No other product maximizes a buildings energy efficiency more cost effectively than Triple Seal Energy Sill Sealer™ by Weather-Bloc.
Stacks Image 5136
Stacks Image 5174
Stacks Image 5180
Building air leakage is known as infiltration, which is introduction of outside air into a building, via gaps, cracks, door, windows or other unplanned openings. Whenever there is infiltration, there is corresponding exfiltration elsewhere in the building. In winter, air infiltration can result in warm, moist indoor air moving into cold envelope cavities.Air infiltration can cause condensation to occur in the structure, resulting in mold, decay and rot. Infiltration is usually caused by wind, "the stack effect", and/or mechanical equipment in the structure.
Stacks Image 5186
Wind creates a positive pressure on the windward face. On the opposite side of the building, negative pressure is created which pulls the air out of the building. Wind causes infiltration on one side of a building and exfiltration on the other.
The “stack effect” is when warm air moves upward in a building. This happens in summer and winter, but is most pronounced in the winter because indoor-outdoor temperature differences are the greatest. Warm air rises because it’s lighter than cold air. So when indoor air is warmer than the outdoor air, it escapes out of the upper levels of the building, through open windows, ventilation openings, or penetrations and cracks in the building envelope. The rising warm air reduces the pressure in the base of the building, forcing cold air to infiltrate through open doors, windows, or other openings. The stack effect basically causes air infiltration on the lower portion of a building and exfiltration on the upper part.

Mechanical equipment such as fans and blowers causes the movement of air within buildings and through enclosures, which can generate pressure differences. If more air is exhausted from a building than is supplied, a net negative pressure is generated, which can induce unwanted airflow through the building envelope. Bathroom exhaust fans, clothes dryers, built-in vacuum cleaners, dust collection systems, and range hoods all exhaust air from a building. This creates a negative pressure inside the building. If the enclosure is airtight or the exhaust flow rate high, large negative pressures can be generated.

Plugging crack or opening in a building is critical to a building performance in regards to energy usage and long-term durability. Creating a better balanced building envelope systems can play a important roll in health and safety of its occupants. Reduction in air infiltration can reduce harmful mold, have fewer drafts and can create better performance from ventilation systems.

Weather-Bloc's Triple Seal Energy Sill Sealer is the world's most advanced solution to the "box sill/ plate line" dilemma. Almost 100% of all buildings being built today use a non-crossed linked foam as a sill sealer. This type of foam was never designed as a gasket and can not seal long-term. Non-Crossed linked foams collapse once weight is applied on it, similar to bubble wrap. When the building dries out and the lumber framing and concrete foundation shrinks, large voids are left behind for both air and moisture to infiltrate.

Stacks Image 5787
Weather-Bloc Systems is the first company that offers a gasket sill sealer and for added protection from abnormal shrinkage and voids we developed Max-Shield a peel & stick perimeter sill flashing that gets applied once the floor deck is in place to assure a precise location and accurate installation. This winning combination has been shown to reduce Utility costs by over 35%.
Energy Triple Seal seal is better than Protecto Energy Sill Sealer or Triple Guard Energy Sill Sealer. Seals off three adhesive membrane areas and stops infiltration from framing and foundation, sill plate, mud sill and other interfaces. The only true self-adhesive air and moisture sill barrier with a cross-linked gasket.